Back to top
SensoDirect Lovibond Tintometer
SensoDirect Lovibond Tintometer

SensoDirect Lovibond Tintometer

MOQ : 1 Unit

SensoDirect Lovibond Tintometer Specification

  • Temperature Range
  • 0 - 50 C
  • Resolution
  • 0.01 mg/L
  • Humidity %
  • up to 95% non-condensing
  • Sensor Type
  • Galvanic oxygen sensor
  • Connectivity Type
  • No data interface (manual logging)
  • Capacity
  • Single sample measurement
  • Measurement Range
  • 0.01 19.99 mg/L (O2)
  • Material
  • Plastic (robust housing)
  • Power Supply
  • Battery (1 x 9V); optional external power supply
  • Power Consumption
  • Low
  • Accuracy
  • 1% FS
  • Display Type
  • Digital LCD
  • Range
  • 0.01 19.99 mg/L
  • Sensor Cable Length
  • 1.5 meters
  • Calibration
  • Manual 1 or 2 point standard
  • Equipment Type
  • Portable Dissolved Oxygen Meter
  • Protection Class
  • IP 65
  • Operating Modes
  • Measurement and calibration
  • Replacement Sensor
  • Available
  • Response Time
  • Less than 30 seconds
  • Dimensions
  • 175 x 85 x 35 mm
  • User Interface
  • Simple keypad
  • Weight
  • Approx. 300 g (with battery)
 

SensoDirect Lovibond Tintometer Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Payment Terms
  • Cheque
  • Supply Ability
  • 20 Units Units Per Month
  • Delivery Time
  • 4-6 Week
  • Packaging Details
  • International Standard.
  • Main Domestic Market
  • North India
 

About SensoDirect Lovibond Tintometer

We feel proud to introduce as one of the renowned suppliers of the finest SensoDirect Lovibond Tintometer in the market. This meter is ideal for measuring pH, redox, dissolved, oxygen, conductivity and TDS level. It is designed with an intuitive user interface and easy to read display. Also, our provided meter contains electrodes, buffer solution and sturdy handy case. In addition to this, our offered SensoDirect Lovibond Tintometer has a real-time data logger.  

Key features:

  • Large digital display
  • Suitable for pool and surface water applications
  • Also, used in laboratories


Effortless Measurement in the Field

Thanks to its lightweight design (only 300g including battery) and portable dimensions, the SensoDirect Lovibond Tintometer is ideal for on-site dissolved oxygen testing. Its single-sample analysis and simple calibration processes make it well-suited for fieldwork, laboratories, and educational use.


Reliability and Durability

Protected by an IP65-rated robust plastic housing, this meter withstands harsh environments and high humidity (up to 95%, non-condensing). The galvanic oxygen sensor and the option for sensor replacement ensure long-term performance and consistent accuracy.


Easy Operation and Maintenance

The intuitive keypad and digital LCD display enable quick measurements and calibration. Manual logging helps maintain data integrity even without digital connectivity, and battery operation means you can use the device anywhere without the need for mains power.

FAQs of SensoDirect Lovibond Tintometer:


Q: How do I calibrate the SensoDirect Lovibond Tintometer?

A: Calibration is performed manually using either a one or two-point standard. Access the calibration mode via the simple keypad and follow the on-screen instructions for accurate sensor adjustment.

Q: What is the typical response time when measuring dissolved oxygen?

A: The meter provides dissolved oxygen readings in less than 30 seconds, ensuring quick and efficient testing in diverse environments.

Q: When should the sensor of the meter be replaced?

A: Replacement is recommended when calibration becomes unreliable, or if you notice a decline in measurement accuracy. Replacement sensors are available for purchase from authorised distributors or suppliers in India.

Q: Where can I use this dissolved oxygen meter?

A: It is perfect for use in laboratories, field sampling, aquaculture, water treatment facilities, and educational settingswherever portable and accurate dissolved oxygen measurements are needed.

Q: What is the process for taking a measurement with this device?

A: Insert the sensor into your sample, select the measurement mode on the keypad, and read the result directly from the digital LCD display. Valid measurements are achieved rapidly, within 30 seconds.

Q: How does the IP65 protection benefit the user?

A: IP65 protection means the device is dust-tight and protected against water jets, making it suitable for demanding environments where moisture and dust are common.

Q: What are the usage benefits of manual logging without data interface?

A: Manual logging ensures data control and reliability in environments without digital infrastructure, maintaining operational simplicity and focusing on straightforward, accurate measurements.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Lovibond Water Testing Equipments Category

Turbidity Meter - TB 300 IR

Turbidity Meter - TB 300 IR

Minimum Order Quantity : 1 Unit

Range : 0 to 1000 NTU

Display Type : Other, Digital LCD display

Measurement Range : 0 1000 NTU

Accuracy : 2% of full scale

Material : ABS plastic body

Photometer MD 600

Photometer MD 600

Minimum Order Quantity : 1 Unit

Range : Varies by parameter and reagent (0.01 to 10.0 mg/L for typical parameters)

Display Type : Other, Large backlit graphic LCD

Measurement Range : Depends on test parameter (typical: 0.0110 mg/L)

Accuracy : 1.5 % FS (factory calibration)

Material : ABS plastic housing

Single Beam Spectrophotometer

Single Beam Spectrophotometer

Minimum Order Quantity : 1 , , Box

Range : 1901000 nm

Display Type : Other, 4digit LED display

Measurement Range : 0200%T, 0.3 to 3A, 01999C

Accuracy : 0.5%T

Material : Metal and highquality plastic body

Quest UV

Quest UV

Range : 0 9999 W/cm

Display Type : Other, Digital LCD Display

Measurement Range : 0 9999 W/cm

Accuracy : 2% of reading