Back to top
BOD System
BOD System

BOD System

MOQ : 1 Box

BOD System Specification

  • Connectivity Type
  • RS232 interface (optional)
  • Pressure Range
  • Atmospheric
  • Measurement Range
  • Up to 1999 mg/L BOD
  • Sensor Type
  • Oxygen Sensor
  • Capacity
  • 6 or 12 bottles (as per model)
  • Humidity %
  • Upto 85% RH
  • Frequency
  • 50 Hz
  • Temperature Range
  • 5°C to 60°C
  • Resolution
  • 0.1 mg/L
  • Equipment Type
  • Biochemical Oxygen Demand (BOD) System
  • Material
  • Stainless Steel and Acrylic
  • Power Supply
  • 230V AC, 50Hz single phase
  • Power Consumption
  • Approx. 250W
  • Accuracy
  • High accuracy with microprocessor-based controller
  • Display Type
  • Digital LED display
  • Range
  • 0-1999 mg/L
  • Control System
  • Microprocessor-based automatic control
  • Alarms
  • Audio/Visual alarms for temperature fluctuation
  • Safety Features
  • Over-temperature protection
  • Inner Chamber
  • Corrosion-resistant stainless steel
  • Bottle Size Support
  • 300ml BOD bottles
  • Sample Capacity
  • 12 bottles (Standard)
  • Cooling Capacity
  • Sufficient for BOD incubation
  • Refrigeration
  • Hermetically sealed compressor
  • Operating Environment
  • Laboratory, Indoor
  • Voltage Fluctuation Protection
  • Built-in stabilizer
  • Display Resolution
  • Clear 4-digit LED
  • Door Type
  • Double-walled insulated door
 

BOD System Trade Information

  • Minimum Order Quantity
  • 1 Box
  • Supply Ability
  • 20 Boxes Per Day
  • Delivery Time
  • 4-6 Days
  • Sample Available
  • Yes
  • Main Domestic Market
  • Chandigarh, Punjab, Delhi, Rajasthan, Himachal Pradesh, Uttarakhand, Uttar Pradesh, Haryana
 

About BOD System

We are known for supplying BOD System which is ideal for determining the activity of biological. This system is perfect to be used in wastewater treatment plant, analytical laboratories and research lab. It is recognized as an innovative and mercury-free solution for biological oxygen demand analysis. Our provided system is featured with a microprocessor controlled pressure transducer to transfer BOD value directly to display. Furthermore, this  BOD System can automatic start after temperature equalization.

Key features:

  • Utilized as a basis to detect biologically degradable organic matter in water
  • Come with easy to use software
  • Provide accurate results that stand the test of time



Advanced Control and Safety Features

Equipped with a microprocessor-based automatic controller, the system provides high-precision temperature regulation and error minimization. Built-in over-temperature protection, voltage stabilization, and audio/visual alarms for temperature fluctuations further guarantee operational safety.


Robust Construction for Laboratory Use

With a double-walled insulated door, stainless steel inner chamber, and acrylic components, this BOD system is engineered for durability and corrosion resistance. The hermetically sealed refrigeration compressor ensures efficient cooling within the temperature range of 5C to 60C.


Optimized Sample Handling

Accommodating either 6 or 12 standard 300ml BOD bottles, this system supports flexible sample loading as per model selection. The systems LED display provides clear, real-time measurements, while the optional RS232 interface enables seamless data export for enhanced traceability.

FAQs of BOD System:


Q: How does the microprocessor-based automatic control improve BOD analysis?

A: The microprocessor-based control system provides precise temperature regulation, enhances measurement accuracy, and automatically manages incubation processes, reducing user intervention and minimizing potential errors during BOD analysis.

Q: What bottle sizes and sample capacities are supported by the BOD system?

A: This BOD system is compatible with standard 300ml BOD bottles and is available in variants supporting either 6 or 12 bottles, allowing flexibility for different laboratory sample workloads.

Q: When should the systems alarms be expected to activate?

A: The built-in audio and visual alarms will activate in the event of temperature fluctuations or deviations from set parameters, alerting users instantly to potential issues that need attention, thus safeguarding sensitive samples.

Q: Where is this BOD system ideally used?

A: Designed for indoor laboratory environments, the BOD system is suitable for academic, industrial, and environmental monitoring labs across India that require accurate biochemical oxygen demand measurements.

Q: What is the process for protecting samples from power and temperature fluctuations?

A: The unit integrates a built-in stabilizer for voltage fluctuation protection and over-temperature safety mechanisms to ensure stable operation and maintain optimal conditions throughout the BOD incubation period.

Q: How does the optional RS232 interface benefit laboratory data management?

A: The optional RS232 connectivity allows easy transfer of BOD measurement data to computers or laboratory management systems, streamlining record-keeping and facilitating comprehensive data analysis.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Lovibond Water Testing Equipments Category

Quest UV

Quest UV

Minimum Order Quantity : 1 Box

Range : 0 9999 W/cm

Humidity % : < 85% RH

Capacity : Continuous Measurement

Sensor Type : UV Sensor, Photodiode Based

Material : ABS Housing

Lovibond Colour Measurement

Lovibond Colour Measurement

Minimum Order Quantity : 1 Box

Range : 0 70 Lovibond units

Humidity % : <80% RH noncondensing

Capacity : Single sample measurement at a time

Sensor Type : Photoelectric sensor

Material : Powder Coated Metal & ABS Body

Turbidity Meter TB210IR

Turbidity Meter TB210IR

Minimum Order Quantity : 1 Box

Range : 0 to 1000 NTU

Humidity % : Up to 85% RH

Capacity : Single Cell Measurement

Sensor Type : Photodiode (Silicon)

Material : ABS Plastic Body

Turbidity Meter - TB 300 IR

Turbidity Meter - TB 300 IR

Minimum Order Quantity : 1 Box

Range : 0 to 1000 NTU

Humidity % : Up to 80% RH

Capacity : Single cell sample, 30 mm path length

Sensor Type : Infrared LED Sensor

Material : ABS plastic body