About Turbidity Meter TB210IR
Specification
| Brand | Lovibond |
| Usage/Application | Drinking Water Treatment , Pool Water Control , Pool Water Treatment , Waste Water Treatment |
| Accuracy | +- 2.5 % of reading, or +- 0.01 NTU, whichever is big1ger, in the range of 0.01 - 500 NTU +- 5 % of r |
| Light Source | Infra Red |
Infrared Accuracy with ISO CalibrationThe TB210IR employs an infrared LED light source at 850 nm and follows a nephelometric (90 scattering) operation, enhancing measurement precision even in colored samples. It is calibrated using Formazin standards across several points, ensuring dependable results that align with ISO 7027 compliance.
User-Friendly Operation and DisplayDesigned with a clear 4-digit red LED display and simple controls, the TB210IR streamlines turbidity measurements. Its benchtop design and 25 mm glass cuvette compatibility allow for easy handling and sample preparation, making it suitable for routine laboratory analyses.
Durable and Efficient DesignConstructed from robust ABS plastic and weighing approximately 2.5 kg, the instrument is both lightweight and durable. The low power consumption and single cell measurement capability make it an efficient choice for a variety of laboratory or field setups within India.
FAQs of Turbidity Meter TB210IR:
Q: How do I calibrate the Turbidity Meter TB210IR?
A: Calibration of the TB210IR is performed using Formazin standards at 0, 100, and 1000 NTU. Simply insert the calibration cuvettes sequentially and follow the on-screen prompts to complete the process, ensuring accuracy in subsequent measurements.
Q: What types of samples can be measured with this turbidity meter?
A: The TB210IR is designed for a wide range of liquid samples, best suited for non-condensing, dust-free water and similar solutions. The sample should be placed in a 25 mm diameter glass cuvette, with a volume of 1015 ml.
Q: When should I recalibrate the instrument?
A: Regular recalibration is recommended before any critical measurement series, or as part of routine maintenance, especially if the instrument has not been used for a while or after changing the working environment or sample type.
Q: Where should the TB210IR be installed for optimal results?
A: Position the TB210IR on a stable benchtop in a non-condensing, dust-free laboratory environment. The ambient temperature should be between 5C to 45C, with relative humidity up to 85% to maintain optimal performance.
Q: What is the measurement range and accuracy of this device?
A: The device offers a measurement range of 0 to 1000 NTU, with a resolution of 0.1 NTU and an accuracy of 3% of full scale (F.S.), ensuring reliable quantification of turbidity across various applications.
Q: How is the measurement process conducted with the TB210IR?
A: Simply fill the provided 25 mm glass cuvette with 1015 ml of your sample, insert it into the measurement slot, and use the straightforward controls to obtain readings on the LED display. Calibration may be required to maintain accuracy.
Q: What are the primary benefits of using the TB210IR Turbidity Meter?
A: The TB210IR provides precise, ISO-compliant turbidity readings with minimal sample volume and user intervention. Its robust build, ease of use, and reliable calibration make it suitable for both routine laboratory analysis and quality control protocols in industrial settings.