Turbidity Meter TB210IR
Turbidity Meter TB210IR

Turbidity Meter TB210IR

MOQ : 1 Box

Turbidity Meter TB210IR Specification

  • Humidity %
  • Up to 85% RH
  • Measurement Range
  • 0 1000 NTU
  • Sensor Type
  • Photodiode (Silicon)
  • Resolution
  • 0.1 NTU
  • Frequency
  • 50 Hz
  • Pressure Range
  • Atmospheric
  • Capacity
  • Single Cell Measurement
  • Temperature Range
  • 5C to 45C
  • Equipment Type
  • Digital Turbidity Meter
  • Material
  • ABS Plastic Body
  • Power Supply
  • 230 V 10% AC, 50 Hz
  • Power Consumption
  • 10 W
  • Accuracy
  • 3% of F.S.
  • Display Type
  • 4 Digit Red LED Display
  • Range
  • 0 to 1000 NTU
  • Sample Volume
  • 10-15 ml
  • Instrument Weight
  • Approx. 2.5 kg
  • Calibration
  • With Formazin Standards (0, 100 and 1000 NTU)
  • Sample Cell Size
  • 25 mm Diameter Glass Cuvettes
  • Light Source
  • Infrared LED (850 nm)
  • Mounting Type
  • Benchtop
  • Operation Principle
  • Nephelometric (90 Scattering)
  • Environmental Conditions
  • Non-condensing, Dust Free Environment
  • Standards Compliance
  • ISO 7027
  • Dimensions
  • 285 x 235 x 130 mm (L x W x H)
 

Turbidity Meter TB210IR Trade Information

  • Minimum Order Quantity
  • 1 Box
  • Supply Ability
  • 20 Boxes Per Day
  • Delivery Time
  • 4-6 Days
  • Sample Available
  • Yes
  • Main Domestic Market
  • Chandigarh, Punjab, Rajasthan, Delhi, Himachal Pradesh, Uttarakhand, Uttar Pradesh, Haryana
 

About Turbidity Meter TB210IR

Specification

Brand

Lovibond

Usage/Application

Drinking Water Treatment , Pool Water Control , Pool Water Treatment , Waste Water Treatment

Accuracy

+- 2.5 % of reading, or +- 0.01 NTU, whichever is big1ger, in the range of 0.01 - 500 NTU  +- 5 % of r

Light Source

Infra Red

 



Infrared Accuracy with ISO Calibration

The TB210IR employs an infrared LED light source at 850 nm and follows a nephelometric (90 scattering) operation, enhancing measurement precision even in colored samples. It is calibrated using Formazin standards across several points, ensuring dependable results that align with ISO 7027 compliance.


User-Friendly Operation and Display

Designed with a clear 4-digit red LED display and simple controls, the TB210IR streamlines turbidity measurements. Its benchtop design and 25 mm glass cuvette compatibility allow for easy handling and sample preparation, making it suitable for routine laboratory analyses.


Durable and Efficient Design

Constructed from robust ABS plastic and weighing approximately 2.5 kg, the instrument is both lightweight and durable. The low power consumption and single cell measurement capability make it an efficient choice for a variety of laboratory or field setups within India.

FAQs of Turbidity Meter TB210IR:


Q: How do I calibrate the Turbidity Meter TB210IR?

A: Calibration of the TB210IR is performed using Formazin standards at 0, 100, and 1000 NTU. Simply insert the calibration cuvettes sequentially and follow the on-screen prompts to complete the process, ensuring accuracy in subsequent measurements.

Q: What types of samples can be measured with this turbidity meter?

A: The TB210IR is designed for a wide range of liquid samples, best suited for non-condensing, dust-free water and similar solutions. The sample should be placed in a 25 mm diameter glass cuvette, with a volume of 1015 ml.

Q: When should I recalibrate the instrument?

A: Regular recalibration is recommended before any critical measurement series, or as part of routine maintenance, especially if the instrument has not been used for a while or after changing the working environment or sample type.

Q: Where should the TB210IR be installed for optimal results?

A: Position the TB210IR on a stable benchtop in a non-condensing, dust-free laboratory environment. The ambient temperature should be between 5C to 45C, with relative humidity up to 85% to maintain optimal performance.

Q: What is the measurement range and accuracy of this device?

A: The device offers a measurement range of 0 to 1000 NTU, with a resolution of 0.1 NTU and an accuracy of 3% of full scale (F.S.), ensuring reliable quantification of turbidity across various applications.

Q: How is the measurement process conducted with the TB210IR?

A: Simply fill the provided 25 mm glass cuvette with 1015 ml of your sample, insert it into the measurement slot, and use the straightforward controls to obtain readings on the LED display. Calibration may be required to maintain accuracy.

Q: What are the primary benefits of using the TB210IR Turbidity Meter?

A: The TB210IR provides precise, ISO-compliant turbidity readings with minimal sample volume and user intervention. Its robust build, ease of use, and reliable calibration make it suitable for both routine laboratory analysis and quality control protocols in industrial settings.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Lovibond Water Testing Equipments Category

BOD Analyzer

BOD Analyzer

Price Range 250000.00 - 350000.00 INR / Box

Minimum Order Quantity : 1 Box

Accuracy : 0.1 mg/L

Power Supply : 230 V AC, 50 Hz

Range : 0400 mg/L

Temperature Range : 5C to 50C

Lovibond Colour Measurement

Lovibond Colour Measurement

Minimum Order Quantity : 1 Box

Accuracy : 0.05 Lovibond units

Power Supply : 230 V AC, 50 Hz

Range : 0 70 Lovibond units

Temperature Range : 10C to 40C

Spectrophotometer Equipments

Spectrophotometer Equipments

Minimum Order Quantity : 1 Box

Accuracy : 0.5% T

Power Supply : 230V AC, 50 Hz

Range : 190 to 1100 nm

Temperature Range : 10C to 40C

Photometer-MD100 Equipment

Photometer-MD100 Equipment

Minimum Order Quantity : 1 Box

Accuracy : 1% FS (depending on test parameter)

Power Supply : 4 x AA or alkaline batteries

Range : Varies according to selected method

Temperature Range : 5C to 40C