Back to top
Colour Analysis System
Colour Analysis System

Colour Analysis System

MOQ : 1 , , Box

Colour Analysis System Specification

  • Display Type
  • Digital LCD
  • Specimen Size
  • Customizable (standard: 100 x 100 mm)
  • Frequency
  • 50Hz
  • Response Time
  • < 2 sec
  • Equipment Type
  • Colour Analysis System
  • Features
  • High precision, easy calibration, user-friendly interface
  • Humidity
  • 20% 90% RH
  • Measuring Range
  • 400 700 nm
  • Number of Specimens
  • 1 5
  • Automation Grade
  • Semi-automatic
  • Test Range
  • Full visible spectrum
  • Operating Voltage
  • 220V
  • Accuracy
  • 0.01
  • Port Size
  • USB / RS232
  • Temperature
  • 0C 50C
  • Max Height
  • 300 mm
  • Resolution
  • 0.01 nm
  • Interface Type
  • USB, RS232, Ethernet
  • Power Supply
  • 220V AC, 50Hz
  • Application
  • Color measurement, textiles, plastics, coating, laboratory analysis
  • Mounting Type
  • Benchtop
  • Usage
  • Laboratory, industrial
  • Capacity
  • High capacity for batch testing
  • Machine Weight
  • 25 kg
  • Test Speed
  • Standard
  • Test Width
  • Adjustable
  • Test Stroke
  • Variable
  • Control Mode
  • Automatic / Manual
  • Operating Environment
  • Indoor, Dust Free
  • Analysis Capability
  • CIELAB, CIELCH, Hunter, CMC, E, Whiteness, Yellowness
  • Power Consumption
  • < 60 W
  • Software Compatibility
  • Windows 7/8/10
  • Data Output
  • USB Storage/ PC Connectivity / Printer
  • Light Source
  • D65, A, TL84 (multiple selectable light sources)
  • Dimensions
  • 450 x 300 x 250 mm (L x W x H)
  • Calibration Method
  • Standard white plate auto calibration
  • Sensor Type
  • CMOS photodiode array
 

Colour Analysis System Trade Information

  • Minimum Order Quantity
  • 1 , , Box
  • Supply Ability
  • 20 Boxes Per Day
  • Delivery Time
  • 4-6 Days
  • Main Domestic Market
  • All India
 

About Colour Analysis System

Colour Analysis System is a kind of prismatic optical system which is highly appreciated for providing perfect color match. It comprises gas filters that are arranged with adjacent field of view and tungsten-halogen light source. This system is known to have user-friendly operation with long service life. It is also equipped with superior quality integral blue filter for standardization of light. Colour Analysis System gives flexibility to remove white plastic liner present in sample chamber so as to assure easy cleaning in case of spillage. It is highly appreciated for assuring excellent performance with easy to maintain nature. 


Versatile Colour Analysis for Precise Results

Engineered for laboratories and industrial settings, this colour analysis system offers exceptional sensitivity and flexibility. The combination of selectable light sources and advanced calibration ensures accuracy regardless of the sample type or testing demands. Its user-friendly interface and digital LCD display make conducting and interpreting tests simpler than ever.


Adaptable Measurement for Diverse Applications

With adjustable test width and stroke, as well as high-capacity batch testing, this system adapts to a variety of color assessment scenariostextiles, plastics, coatings, and more. The customizable specimen size and advanced analysis capabilities (including CIELAB, E, Whiteness, and Yellowness) enable comprehensive evaluations required by strict industry standards.


Efficient Operation and Data Management

Seamlessly integrated with USB, RS232, and Ethernet ports, this system streamlines data handling and reporting. Thanks to swift response time and compatibility with major Windows versions, it allows fast, accurate testing in modern laboratory environments, supporting productivity and quality assurance processes.

FAQs of Colour Analysis System:


Q: How is calibration performed on the Colour Analysis System?

A: Calibration is achieved using a standard white plate through an automatic process, ensuring accurate and repeatable results for every measurement session.

Q: What types of samples and industries can this system analyze?

A: The system is suitable for analyzing color in textiles, plastics, coatings, and other laboratory applications. Its customizable test width and specimen size accommodate various sample types across multiple industries.

Q: When should I use different light sources (D65, A, TL84)?

A: Different light sources simulate varied real-world lighting conditions: D65 represents daylight, A simulates incandescent lighting, and TL84 is for store-like fluorescent light. Selecting the appropriate light source helps assess how colors appear in different environments.

Q: Where can the Colour Analysis System be installed and operated?

A: This system is designed for dust-free, indoor environments such as laboratories or industrial quality control areas, functioning within 0C 50C and 20% 90% relative humidity for optimal performance.

Q: What is the process for conducting a color measurement test?

A: Place the specimen on the benchtop mount, select the required light source, and initiate the test using automatic or manual controls. Data is collected using the CMOS photodiode array and results are displayed on the digital LCD, with options for USB, RS232, or Ethernet data output.

Q: How does the system benefit laboratories and industrial facilities?

A: It delivers high-precision, fast response color analysis, batch testing capability, and user-friendly operation. The system streamlines workflow, boosts productivity, and supports quality assurance for color-critical processes.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Lovibond Colour Measurement Instruments Category

Measurement Tintometer

Measurement Tintometer

Minimum Order Quantity : 1 Box

Temperature : 5C to 45C operating range

Power Supply : 230 V AC, 50 Hz

Application : Color measurement in water analysis, industrial fluids, laboratory samples

Mounting Type : Benchtop

Control Mode : Manual

Spectrocolorimeter Tintometer

Spectrocolorimeter Tintometer

Minimum Order Quantity : 1 Unit

Temperature : Operating range 10C 40C

Power Supply : 230V AC, 50Hz

Application : Color analysis and grading for liquids

Mounting Type : Benchtop

Control Mode : Digital touch panel

Oil Measuring Instrument

Oil Measuring Instrument

Minimum Order Quantity : 1 , , Box

Temperature : 0C to 50C

Power Supply : Not Required (Manual Operation)

Application : Used for precise measurement of oil quantity in industrial and laboratory settings

Mounting Type : Benchtop

Control Mode : Analog

Portable Reflectivity Meter

Portable Reflectivity Meter

Minimum Order Quantity : 1 Unit

Temperature : 0C to 40C

Power Supply : 2 x AA Batteries

Application : Measuring surface reflectivity of coatings, plastics, glass, etc.

Mounting Type : Handheld

Control Mode : Manual